Worcester 30i System Compact Instrukcja Obsługi

Przeglądaj online lub pobierz Instrukcja Obsługi dla Grzejniki wodne i kotły Worcester 30i System Compact. Worcester 30i System Compact Technical data Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 21
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
1
The Greenstar CDi gas-fired
condensing regular & system
boiler series
Technical and specification information
Voted Domestic Heating Product of the Year in 2005 & 2006
BBT1253 G_CDi Rg+Sys TS c08_07 25/6/07 09:21 Page 1
Przeglądanie stron 0
1 2 3 4 5 6 ... 20 21

Podsumowanie treści

Strona 1 - The Greenstar CDi gas-fired

1The Greenstar CDi gas-firedcondensing regular & system boiler seriesTechnical and specification informationVoted Domestic Heating Product of the

Strona 2 - Worcester, Bosch Group

1918Greenstar CDi regular & system boiler series horizontal fluing options Option 1Standard horizontal flue assemblyFlue components required Flue

Strona 3 - The Greenstar CDi condensing

2120Maximum total straight flue length100mm dia 125mm dia30CDi Conventional 7,900mm 18,500mm40CDi Conventional 2,600mm 12,500mm30CDi System 7,900mm 1

Strona 4 - System model

2322Greenstar CDi regular & system boiler series vertical fluing options The Greenstar CDi series have the choice of 2 differentlysized vertical R

Strona 5 - Increased SAP ratings

2524Option 3Vertical balanced flue system with two 90º bendsFlue components required Flue Diameter Description Quantity Worcester Part No.30CDi Conven

Strona 6

2726100mm dia horizontal telescopic flue lengths with a 60mm dia plume management systemThe maximum effective straight flue lengths (L) are statedoppo

Strona 7 - Installing the Greenstar CDi

2928Flue components required Flue Diameter Description Quantity Worcester Part No.30CDi Conventional60mm Plume Management Kit 1 7 716 191 08660mm 1,00

Strona 8

3130Plastic pipeworkThe use of plastic pipework is acceptable. However, someplastics are permeable to oxygen and must be avoided. Onlypipework with a

Strona 9 - Flue terminal positioning

3332Greenstar CDi series accessoriesNote: For information on the Condensfit II Telescopic Flue System and Plume Management Kit, please see dedicated f

Strona 10 - 100mm dia 125mm dia

3534Notes NotesBBT1253 G_CDi Rg+Sys TS c08_07 25/6/07 09:21 Page 34

Strona 11

A complete after-sales serviceAll the technical advice you needSparesGenuine replacement parts for all Worcester boilers arereadily available from sto

Strona 12 - (inc. terminal)

32Worcester and you. Making a difference.Contents PageThe Greenstar CDi gas-fired condensing 4 - 7regular & system boiler series Optional plug-in

Strona 13 - 500mm (M)

BangorBradfordClay CrossWorcesterWest ThurrockLauderDundee3938The very best training programmesfrom Worcester Worcester training coursesWorcester has

Strona 14 - 60mm dia

www.worcester-bosch.co.ukUseful numbersSalesTel: 01905 752640Fax: 01905 456445Spare PartsTel: 01905 752576Fax: 01905 754620Technical (Pre & Post S

Strona 15

54The Greenstar CDi condensing regular & system boiler seriesIt’s often said that you can’t please everybody all of thetime – but the advanced new

Strona 16 - *Subject to conditions

The Worcester Greenstar CDi Conventional is a wall-mounted, gas-fired condensing ‘heating only’ or regularboiler. The appliance combines, within one c

Strona 17 - *30CDi System only

DT20RF digital RF thermostat with twin channel programmerA wall-mounted RF room thermostat with digital display, combined with a twin channeldigital t

Strona 18 - Notes Notes

The Greenstar CDi Conventionalcondensing boiler – inside storyKey to components1. Aluminium/Silicon WB5 Heat Exchanger2. Pre-mix Fan3. Down Firing Low

Strona 19 - All the technical advice

The Greenstar 30CDi Systemcondensing boiler – inside storyKey to components1. Aluminium/Silicon WB5 Heat Exchanger2. Pre-mix Fan3. Down Firing Low NOx

Strona 20 - 01905 752526

1514Compartment installationThe appliance may be installed in any room, althoughparticular attention is drawn to the requirements of the IEEregulation

Strona 21 - Useful numbers

1716Flue terminal positioningboundaryOPPPPRQQD,EBCAIGHJLFIPHHNMKTerminals adjacent to windows or openings on pitched and flat roofs600mm600mm2000mmThe

Komentarze do niniejszej Instrukcji

Brak uwag